{"id":1851410022473,"title":"ENERDRIVE ePRO Inverter Charger 12V 3000W (BW-EPC3000-12)","handle":"enerdrive-epro-inverter-charger-12v-3000w-bw-epc3000-12","description":"[TABS]\n\u003ch5\u003eProduct Description\u003c\/h5\u003e\n\u003cp\u003eThe main task of the ePRO Combi Inverter Charger is to act as an uninterruptible AC power supply (UPS). In case of a grid\/generator failure or disconnection, the ePRO Combi immediately stops charging the battery, releases the AC transfer switch and activates the inverter which takes over the supply to the connected loads. All this is achieved so fast, that even very critical loads like computers will continue to operate without any problems. In case the grid\/generator is reconnected again and the voltage and frequency are within acceptable limits, the ePRO Combi activates the AC transfer switch and battery charger again, while deactivating the inverter. The connected loads are now supplied again by the grid\/generator without any interruption.\u003c\/p\u003e\n\u003ch3\u003eAdditionally, the ePRO Inverter Charger offers features like :\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Power Boost,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhich temporarily assists weak AC input sources when the connected load needs more power than available from the grid or generator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Current Limit,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhich limits the maximum current consumed from the AC input source by the ePRO Combi. This limit is user adjustable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Factor Corrected AC Input,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhich optimizes energy efficiency and makes sure that the maximum amount of charging current is available from your AC source.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent 4-stage charge programs,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euser programmable to fit any battery type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully programmable inverter, transfer switch and battery charger parameters,\u003c\/strong\u003eusing the Dashboard for Windows software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable alarm relay,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor optimal control of external devices like generator starting or selective load disconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFreely assignable trigger input,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhich allows the user to control the ePRO Combi by external events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature controlled fans,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto guarantee silent operation under less than full load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensated battery charging,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing the standard supplied battery temperature sensor for maximum battery lifetimes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhen installation space is at a premium, but maximum performance is required then look no further than the ePRO Combi range.  With so many internal features the ePRO Combi will provide you with all the requirements for on-board power along with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Power Boost\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– The ePRO Combi is capable of temporarily assisting weak AC input sources when more power is needed than available (i.e. from small generators).  This is beneficial when larger loads than both the generator or the inverter on their own could support; so let the ePRO Combi combine both of the AC sources for maximum load support capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Current Limit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– For those times when you have limited AC supply (i.e. portable generators), you can set the ePRO Combi to only charge at a maximum rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Output Relays\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Providing full configuration options for the alarm contacts PLUS convert external trigger commands into a number of ePRO Combi status changes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003ctable class=\"specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eEPC 2000-12\u003c\/th\u003e\n\u003cth\u003eEPC 3000-12\u003c\/th\u003e\n\u003cth\u003eEPC 3500-24\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(1)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ePnom\u003c\/td\u003e\n\u003ctd\u003e1800W\u003c\/td\u003e\n\u003ctd\u003e2600W\u003c\/td\u003e\n\u003ctd\u003e2800W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP10minutes\u003c\/td\u003e\n\u003ctd\u003e2100W\u003c\/td\u003e\n\u003ctd\u003e3200W\u003c\/td\u003e\n\u003ctd\u003e3800W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePsurge\u003c\/td\u003e\n\u003ctd\u003e4000W\u003c\/td\u003e\n\u003ctd\u003e5000W\u003c\/td\u003e\n\u003ctd\u003e6500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage \/ frequency\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e230 Vac ± 2% \/ 50 Hz ± 0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput waveform\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e230 Vac ± 2% \/ 50 Hz ± 0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage (± 3% tolerance): Nominal\u003c\/td\u003e\n\u003ctd\u003e12V\u003c\/td\u003e\n\u003ctd\u003e12V\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e10.5\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(2)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e– 16 Vdc\u003c\/td\u003e\n\u003ctd\u003e10.5\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(2)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e– 16 Vdc\u003c\/td\u003e\n\u003ctd\u003e21\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(2)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e– 32 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum efficiency\u003c\/td\u003e\n\u003ctd\u003e92%\u003c\/td\u003e\n\u003ctd\u003e92%\u003c\/td\u003e\n\u003ctd\u003e93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load power consumption\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(2)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e[ASB]\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;20 W [3.5 W]\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;20 W [3.5 W]\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;20 W [4.0 W]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003e\u003cb\u003eCharger stage\u003c\/b\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input voltage\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e185 – 270 Vac \/ 45 – 65 Hz \/ PF \u0026gt; 0.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous charging current\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(4)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003ctd\u003e70A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard charge voltage (bulk \/ float @ 25°C)\u003c\/td\u003e\n\u003ctd\u003e14.3V \/ 13.3V (programmable)\u003c\/td\u003e\n\u003ctd\u003e14.3V \/ 13.3V (programmable)\u003c\/td\u003e\n\u003ctd\u003e28.6V \/ 26.6V (programmable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge algorithm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eIUoUoP, intelligent 4-stage, temperature compensated (programmable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003e\u003cb\u003eAC Transfer Switch\u003c\/b\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous current\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e30 Ams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer time (typical)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0 ms (inverter to mains) \/ \u0026lt;5 ms (mains to inverter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003e\u003cb\u003eGeneral\u003c\/b\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eePROLink enabled\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003ehigh\/low battery voltage, high temperature, overload, short circuit, high ripple voltage and low AC input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC connections\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eM10 bolt terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC connections\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure body size\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e370 x 431 x 132mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal weight\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e18.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class \/ operating temp. \/ storage temp.\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eIP21 \/ -20°C.. +50°C \/ -40°C.. +80°C (humidity max. 95% non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eComplies with IEC 60335-2-29 including Australian deviations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eNote: Specifications subject to change without notice.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003col\u003e\n\u003cli\u003eMeasured with resistive load at 25°C ambient. Power ratings are subject to a tolerance of 10% and are decreasing as temperature rises with a rate of approx. 1.2%\/°C starting from 25°C. Pnom is a typical value, measured using battery capacities of 200 Ah @ 12 V and 100 Ah @ 24V\u003c\/li\u003e\n\u003cli\u003eUndervoltage limit is dynamic. This limit decreases with increasing load to compensate the voltage drop across cables and connections.\u003c\/li\u003e\n\u003cli\u003eMeasured at nominal input voltage and 25°C.\u003c\/li\u003e\n\u003cli\u003eAt high ambient temperatures, maximum output current shall be reduced automatically.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch5\u003eWarranty\u003c\/h5\u003e\n\u003ctable class=\"specifications\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/TABS]\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-11-12T15:19:43+10:00","created_at":"2018-11-12T15:22:46+10:00","vendor":"Battery Wise","type":"","tags":[],"price":329900,"price_min":329900,"price_max":329900,"available":true,"price_varies":false,"compare_at_price":352500,"compare_at_price_min":352500,"compare_at_price_max":352500,"compare_at_price_varies":false,"variants":[{"id":16893816275017,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"BW-EPC3000-12","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"ENERDRIVE ePRO Inverter Charger 12V 3000W (BW-EPC3000-12)","public_title":null,"options":["Default Title"],"price":329900,"weight":18000,"compare_at_price":352500,"inventory_management":"shopify","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0030\/3162\/9897\/products\/Battery_Wise_epro-combi-3000_79ad816b-4626-46fe-a77d-5307cab6a98d.jpg?v=1542000168"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0030\/3162\/9897\/products\/Battery_Wise_epro-combi-3000_79ad816b-4626-46fe-a77d-5307cab6a98d.jpg?v=1542000168","options":["Title"],"content":"[TABS]\n\u003ch5\u003eProduct Description\u003c\/h5\u003e\n\u003cp\u003eThe main task of the ePRO Combi Inverter Charger is to act as an uninterruptible AC power supply (UPS). In case of a grid\/generator failure or disconnection, the ePRO Combi immediately stops charging the battery, releases the AC transfer switch and activates the inverter which takes over the supply to the connected loads. All this is achieved so fast, that even very critical loads like computers will continue to operate without any problems. In case the grid\/generator is reconnected again and the voltage and frequency are within acceptable limits, the ePRO Combi activates the AC transfer switch and battery charger again, while deactivating the inverter. The connected loads are now supplied again by the grid\/generator without any interruption.\u003c\/p\u003e\n\u003ch3\u003eAdditionally, the ePRO Inverter Charger offers features like :\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Power Boost,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhich temporarily assists weak AC input sources when the connected load needs more power than available from the grid or generator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Current Limit,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhich limits the maximum current consumed from the AC input source by the ePRO Combi. This limit is user adjustable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Factor Corrected AC Input,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhich optimizes energy efficiency and makes sure that the maximum amount of charging current is available from your AC source.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent 4-stage charge programs,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euser programmable to fit any battery type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully programmable inverter, transfer switch and battery charger parameters,\u003c\/strong\u003eusing the Dashboard for Windows software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable alarm relay,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor optimal control of external devices like generator starting or selective load disconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFreely assignable trigger input,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhich allows the user to control the ePRO Combi by external events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature controlled fans,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto guarantee silent operation under less than full load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensated battery charging,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing the standard supplied battery temperature sensor for maximum battery lifetimes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhen installation space is at a premium, but maximum performance is required then look no further than the ePRO Combi range.  With so many internal features the ePRO Combi will provide you with all the requirements for on-board power along with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Power Boost\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– The ePRO Combi is capable of temporarily assisting weak AC input sources when more power is needed than available (i.e. from small generators).  This is beneficial when larger loads than both the generator or the inverter on their own could support; so let the ePRO Combi combine both of the AC sources for maximum load support capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Current Limit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– For those times when you have limited AC supply (i.e. portable generators), you can set the ePRO Combi to only charge at a maximum rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Output Relays\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Providing full configuration options for the alarm contacts PLUS convert external trigger commands into a number of ePRO Combi status changes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003ctable class=\"specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eEPC 2000-12\u003c\/th\u003e\n\u003cth\u003eEPC 3000-12\u003c\/th\u003e\n\u003cth\u003eEPC 3500-24\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(1)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ePnom\u003c\/td\u003e\n\u003ctd\u003e1800W\u003c\/td\u003e\n\u003ctd\u003e2600W\u003c\/td\u003e\n\u003ctd\u003e2800W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP10minutes\u003c\/td\u003e\n\u003ctd\u003e2100W\u003c\/td\u003e\n\u003ctd\u003e3200W\u003c\/td\u003e\n\u003ctd\u003e3800W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePsurge\u003c\/td\u003e\n\u003ctd\u003e4000W\u003c\/td\u003e\n\u003ctd\u003e5000W\u003c\/td\u003e\n\u003ctd\u003e6500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage \/ frequency\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e230 Vac ± 2% \/ 50 Hz ± 0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput waveform\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e230 Vac ± 2% \/ 50 Hz ± 0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage (± 3% tolerance): Nominal\u003c\/td\u003e\n\u003ctd\u003e12V\u003c\/td\u003e\n\u003ctd\u003e12V\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e10.5\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(2)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e– 16 Vdc\u003c\/td\u003e\n\u003ctd\u003e10.5\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(2)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e– 16 Vdc\u003c\/td\u003e\n\u003ctd\u003e21\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(2)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e– 32 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum efficiency\u003c\/td\u003e\n\u003ctd\u003e92%\u003c\/td\u003e\n\u003ctd\u003e92%\u003c\/td\u003e\n\u003ctd\u003e93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load power consumption\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(2)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e[ASB]\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;20 W [3.5 W]\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;20 W [3.5 W]\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;20 W [4.0 W]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003e\u003cb\u003eCharger stage\u003c\/b\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input voltage\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e185 – 270 Vac \/ 45 – 65 Hz \/ PF \u0026gt; 0.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous charging current\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e(4)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003ctd\u003e70A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard charge voltage (bulk \/ float @ 25°C)\u003c\/td\u003e\n\u003ctd\u003e14.3V \/ 13.3V (programmable)\u003c\/td\u003e\n\u003ctd\u003e14.3V \/ 13.3V (programmable)\u003c\/td\u003e\n\u003ctd\u003e28.6V \/ 26.6V (programmable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge algorithm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eIUoUoP, intelligent 4-stage, temperature compensated (programmable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003e\u003cb\u003eAC Transfer Switch\u003c\/b\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous current\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e30 Ams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer time (typical)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0 ms (inverter to mains) \/ \u0026lt;5 ms (mains to inverter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003e\u003cb\u003eGeneral\u003c\/b\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eePROLink enabled\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003ehigh\/low battery voltage, high temperature, overload, short circuit, high ripple voltage and low AC input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC connections\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eM10 bolt terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC connections\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure body size\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e370 x 431 x 132mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal weight\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e18.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class \/ operating temp. \/ storage temp.\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eIP21 \/ -20°C.. +50°C \/ -40°C.. +80°C (humidity max. 95% non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eComplies with IEC 60335-2-29 including Australian deviations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eNote: Specifications subject to change without notice.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003col\u003e\n\u003cli\u003eMeasured with resistive load at 25°C ambient. Power ratings are subject to a tolerance of 10% and are decreasing as temperature rises with a rate of approx. 1.2%\/°C starting from 25°C. Pnom is a typical value, measured using battery capacities of 200 Ah @ 12 V and 100 Ah @ 24V\u003c\/li\u003e\n\u003cli\u003eUndervoltage limit is dynamic. This limit decreases with increasing load to compensate the voltage drop across cables and connections.\u003c\/li\u003e\n\u003cli\u003eMeasured at nominal input voltage and 25°C.\u003c\/li\u003e\n\u003cli\u003eAt high ambient temperatures, maximum output current shall be reduced automatically.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ch5\u003eWarranty\u003c\/h5\u003e\n\u003ctable class=\"specifications\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/TABS]\n\u003cp\u003e \u003c\/p\u003e"}

ENERDRIVE ePRO Inverter Charger 12V 3000W (BW-EPC3000-12)

Product Description
$3,525.00
'Click 'Add To Cart' for Shipping Calculator'
Maximum quantity available reached.
Sku: BW-EPC3000-12

The main task of the ePRO Combi Inverter Charger is to act as an uninterruptible AC power supply (UPS). In case of a grid/generator failure or disconnection, the ePRO Combi immediately stops charging the battery, releases the AC transfer switch and activates the inverter which takes over the supply to the connected loads. All this is achieved so fast, that even very critical loads like computers will continue to operate without any problems. In case the grid/generator is reconnected again and the voltage and frequency are within acceptable limits, the ePRO Combi activates the AC transfer switch and battery charger again, while deactivating the inverter. The connected loads are now supplied again by the grid/generator without any interruption.

Additionally, the ePRO Inverter Charger offers features like :

  • AC Input Power Boost, which temporarily assists weak AC input sources when the connected load needs more power than available from the grid or generator.
  • AC Input Current Limit, which limits the maximum current consumed from the AC input source by the ePRO Combi. This limit is user adjustable.
  • Power Factor Corrected AC Input, which optimizes energy efficiency and makes sure that the maximum amount of charging current is available from your AC source.
  • Intelligent 4-stage charge programs, user programmable to fit any battery type.
  • Fully programmable inverter, transfer switch and battery charger parameters,using the Dashboard for Windows software.
  • Programmable alarm relay, for optimal control of external devices like generator starting or selective load disconnection.
  • Freely assignable trigger input, which allows the user to control the ePRO Combi by external events.
  • Temperature controlled fans, to guarantee silent operation under less than full load conditions.
  • Temperature compensated battery charging, using the standard supplied battery temperature sensor for maximum battery lifetimes.

When installation space is at a premium, but maximum performance is required then look no further than the ePRO Combi range.  With so many internal features the ePRO Combi will provide you with all the requirements for on-board power along with:

  • AC Input Power Boost – The ePRO Combi is capable of temporarily assisting weak AC input sources when more power is needed than available (i.e. from small generators).  This is beneficial when larger loads than both the generator or the inverter on their own could support; so let the ePRO Combi combine both of the AC sources for maximum load support capability.
  • AC Input Current Limit – For those times when you have limited AC supply (i.e. portable generators), you can set the ePRO Combi to only charge at a maximum rate.
  • Alarm Output Relays – Providing full configuration options for the alarm contacts PLUS convert external trigger commands into a number of ePRO Combi status changes.
Model EPC 2000-12 EPC 3000-12 EPC 3500-24
Output power (1) Pnom 1800W 2600W 2800W
P10minutes 2100W 3200W 3800W
Psurge 4000W 5000W 6500W
Output voltage / frequency 230 Vac ± 2% / 50 Hz ± 0.05%
Output waveform 230 Vac ± 2% / 50 Hz ± 0.05%
Input voltage (± 3% tolerance): Nominal 12V 12V 24V
Range 10.5 (2) – 16 Vdc 10.5 (2) – 16 Vdc 21 (2) – 32 Vdc
Maximum efficiency 92% 92% 93%
No load power consumption (2) [ASB] <20 W [3.5 W] <20 W [3.5 W] <20 W [4.0 W]
Charger stage
AC input voltage 185 – 270 Vac / 45 – 65 Hz / PF > 0.95
Maximum continuous charging current (4) 80A 120A 70A
Standard charge voltage (bulk / float @ 25°C) 14.3V / 13.3V (programmable) 14.3V / 13.3V (programmable) 28.6V / 26.6V (programmable)
Charge algorithm IUoUoP, intelligent 4-stage, temperature compensated (programmable)
AC Transfer Switch
Maximum continuous current 30 Ams
Transfer time (typical) 0 ms (inverter to mains) / <5 ms (mains to inverter)
General
ePROLink enabled Yes
Protections high/low battery voltage, high temperature, overload, short circuit, high ripple voltage and low AC input voltage
DC connections M10 bolt terminals
AC connections Screw terminals
Enclosure body size 370 x 431 x 132mm
Total weight 18.5 Kg
Protection class / operating temp. / storage temp. IP21 / -20°C.. +50°C / -40°C.. +80°C (humidity max. 95% non-condensing)
Standards Complies with IEC 60335-2-29 including Australian deviations.
Note: Specifications subject to change without notice.
  1. Measured with resistive load at 25°C ambient. Power ratings are subject to a tolerance of 10% and are decreasing as temperature rises with a rate of approx. 1.2%/°C starting from 25°C. Pnom is a typical value, measured using battery capacities of 200 Ah @ 12 V and 100 Ah @ 24V
  2. Undervoltage limit is dynamic. This limit decreases with increasing load to compensate the voltage drop across cables and connections.
  3. Measured at nominal input voltage and 25°C.
  4. At high ambient temperatures, maximum output current shall be reduced automatically.